Inverter fault codes
This page contains a list of error messages or fault codes that can appear on SOLARRWATT Inverter vision, and suggested remedies for each.
| Error code | Remedy |
|---|---|
| Grid Lost Fault | Grid is interrupted
|
| Grid Volt Fault | Grid voltage outside the normal range
|
| Grid Freq Fault | Grid frequency outside the normal range
|
| PLL_OverTime | Three-phase system accessing single-phase alternating current
|
| 10min Volt Fault | Mains voltage has been outside the normal range for the last 10 minutes
|
| SW Inv Cur Fault | High output current detected by the software
|
| DCI Fault | The DC-related input current is outside the limit value
|
| HW Inv Cur Fault | High output current detected by the hardware.
|
| SW Bus Vol Fault | Out of range bus voltage detected by the software.
|
| Bat Volt Fault | battery voltage error.
|
| SW Bat Cur Fault | high battery current detected by the software.
|
| Iso Fault | the insulation is faulty.
|
| Res Cur Fault | the fault current is high.
|
| PV Volt Fault | PV voltage outside the tolerance range.
|
| SW PV Cur Fault | the software has detected a high PV input current.
|
| Temp Fault | the temperature of the inverter is high.
|
| Ground fault | the grounding is faulty.
|
| Over Load Fault | Overload in grid operation.
|
| Eps Over Load | Overload in grid replacement mode.
|
| Bat Power Low | The battery power is low.
|
| HW Bus Vol Fault | Bus voltage detected by the hardware is outside the standard range.
|
| HW PV Cur Fault | high PV input current detected by the hardware.
|
| HW Bat Cur Fault | high battery current detected by the hardware.
|
| SCI Fault | Communication between Master and Manager has failed.
|
| MDSP SPI Fault | Communication between master and slave has failed.
|
| MDSP Smpl Fault | The master sample detector circuit has failed.
|
| Res Cur HW Fault | residual current detection has failed.
|
| Inv EEPROM Fault | The inverter EEPROM battery is faulty.
|
| PvCon Dir Fault | The PV connections are reversed.
|
| Bat Relay Open | the battery relay is open.
|
| Bat Relay Short Circuit | the battery relay is closed.
|
| Bat Buck Fault | The MOSFET of the battery voltage reduction circuit is defective.
|
| Bat Boost Fault | The MOSFET of the battery boost circuit is faulty or the relay on the battery side of the inverter is not closed. To update to the latest software, make sure at least that the master is updated to 1.69 or higher.
|
| Eps Relay Fault | The EPS relay has failed.
|
| BatCon Dir Fault | The battery connections are reversed.
|
| Grid Relay Fault | The grid relay is open or closed.
|
| RDSP SPI Fault | Communication between master and slave has failed.
|
| RDSP Smpl Fault | The slave sample detector circuit has failed. failed.
|
| ARM EEPROM Fault | The Manager's EEPROM is faulty.
|
Meter Lost Fault G100 State 3 | Communication between meter and inverter is interrupted.
|
| BMS Lost | Communication between BMS and inverter is interrupted.
|
| BMS Ext Fault | Communication between BMS and inverter is interrupted.
|
| BMS Int Fault | DIP switch in the wrong position Communication between the Battery packs is interrupted.
|
| other error messages | Contact SOLARWATT Service. |