Update October 2025

15.10.2025

Release Notes - Version 10.25.40/41.1

General improvements

Changes & new functionality

EM.setup

The EM.setup dashboard has been redesigned with an improved user interface. All settings are now easily accessible in one place.

Network settings: New heading, clearer description, layout fix and updated menu icon

Device search: For systems in Italy, a warning appears that not all devices can be connected to Battery vision

A warning message has been added when creating a PV plant if no free inverter, replacement inverter or S0 meter is found

The feed-in tariff value now defaults to 0ct/kWh (except in Germany, where it defaults to the national value of 8.03ct/kWh)

Various translations for network settings, PV plants, curtailment testing and Location area have been added and improved for Spanish, French, Italian, Dutch and Swedish

SOLARWATT Inverter vision

SOLARWATT Inverter vision inverters will now automatically be detected by the manager; no more manual steps are required to search for this device

Improved support for setups without a battery or meter, including fixing a bug where EM.Setup would show a ghost battery had been detected when one was not installed  

Added curtailment support (forcing the inverter to not use all current generation for self-consumption)

Kostal Plenticore G3 hybrid inverter

Added support for schedules for battery control

Native Modbus connection for Plenticore G3 hybrid inverters is now possible through manual installation

Use of KSEM or KEM-C/-P as energy meter

Monitoring of inverter, battery and meter

Added curtailment support (forcing the inverter to not use all current generation for self-consumption)

my-PV AC Thor i

Models with serial numbers starting with 200103 and 200113 (the UK & Irish model of AC Thor, called AC Thor i) are now supported.

 

Bug fixes

EM.setup

In consumer-only setups: All active consumers including SmartHeater are correctly taken into account (incorrect load summation fixed)

Decimal numbers for PV module power can be entered again with comma or point

After locking the configuration, the link to the summary works again

Input fields when creating a PV plants now react in real time (validation)

Inconsistent inverter configuration for PV plants with S0 meter fixed (battery inverter is correctly displayed as occupied)

Error with serial connection: Baud rate options are no longer displayed twice

Communication

Potential restart loops with offline devices has been fixed.

Meters & measured values

S0 meters: Work values are synchronized correctly again

Shelly EM: Is now also taken into account as a consumer and can be used as an energy meter

FNN base meter: Fixed translation error with baud rate options

Balancing: Bidirectional energy meters are correctly included in the calculation (heat pumps via Shelly now correctly recorded)

Inverters & batteries

SOLARWATT Inverter vision / Battery vision: A number of issues concerning the display of maximum charging/discharging power has been fixed

SOLARWATT Charger max: Error in the scaling factor of the energy values (due to firmware update) fixed → Working values plausible again

Varta: Batteries are displayed correctly again in the cloud

PV optimization: Error with hybrid inverters (Fronius Symo GEN24, Kostal Plenticore, Steca SolBrid) fixed → PV surplus is determined correctly, battery charging is no longer incorrectly interpreted as surplus

UI & user-friendliness

UI error message in the curtailment test module has been expanded with a more detailed error reason

Values for alignment and vertical inclination in the PV plan can be deleted and saved again